Robotics, simulation, education, ergonomics, finger placement, outcomes.Abstract
INTRODUCTION: Robotic surgery for localized prostate cancer offers a greater range of motion attributed to the EndoWrist instruments. Postoperative outcomes are linked to the quality of vesico-urethral anastomosis. Trainees frequently complain of suturing difficulty in a back-handed fashion. We aimed to analyze wrist motion using the DaVinci simulator. We hypothesized that using the thumb and index finger would allow superior surgical proficiency when compared to the middle finger.
METHODS: After institutional review board approval, we recruited 42 medical students in one academic medical center. Students were randomly assigned to start with their thumb and index finger (1&2) or thumb and middle finger (1&3). Three standardized modules were used with nine metrics calculated, including: score, total time, economy of motion, efficiency score, collisions, inaccurate puncture, wound approximation, out of view, and penalty subtotal. Statistical analysis of the metrics was calculated using SPSS.
RESULTS: Three metrics were found to have differences between the finger placement of 1&3compared to 1&2. The number of collisions, wound approximation, and penalty score where 1&3 were used had a lower score in each. The number of collisions was 5.7 less in the 1&3 finger placement (p=0.046). This metric was found to have statistically significant differences between finger placement where 1&3 had a lower score compared to 1&2. The wound approximation score was 0.2 points lower when using the 1&3 placement (p=0.075). Lastly, the penalty assigned was 6.5 points lower when using 1&3 (p=0.069).
CONCLUSIONS: Although finger placement did not affect the overall score of the completed simulation, instrument collisions and unnecessary wound complications may lead to adverse outcomes when using 1&2 despite offering a wider range of motion. This may be due to decreased comfort in hand position. Trainees may be able to improve the effectiveness of their vesico-urethral anastomosis during robotic-assisted radical prostatectomy.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
You, the Author(s), assign your copyright in and to the Article to the Canadian Urological Association. This means that you may not, without the prior written permission of the CUA:
- Post the Article on any Web site
- Translate or authorize a translation of the Article
- Copy or otherwise reproduce the Article, in any format, beyond what is permitted under Canadian copyright law, or authorize others to do so
- Copy or otherwise reproduce portions of the Article, including tables and figures, beyond what is permitted under Canadian copyright law, or authorize others to do so.
The CUA encourages use for non-commercial educational purposes and will not unreasonably deny any such permission request.
You retain your moral rights in and to the Article. This means that the CUA may not assert its copyright in such a way that would negatively reflect on your reputation or your right to be associated with the Article.
The CUA also requires you to warrant the following:
- That you are the Author(s) and sole owner(s), that the Article is original and unpublished and that you have not previously assigned copyright or granted a licence to any other third party;
- That all individuals who have made a substantive contribution to the article are acknowledged;
- That the Article does not infringe any proprietary right of any third party and that you have received the permissions necessary to include the work of others in the Article; and
- That the Article does not libel or violate the privacy rights of any third party.