Introduction: Accurate detection and measurement of renal stones guides clinical decision-making, as stone size predicts spontaneous passage and appropriate surgical management. Non-contrast computed tomography (NCCT) is the reference standard, but ultrasonography (US) is increasingly used for its accessibility, lack of ionizing radiation, and cost. We evaluated US performance at our tertiary referral center, assessing the impact of imaging sequence (NCCT first or US first) on diagnostic accuracy.

Methods: A single-center, retrospective study was performed using data from January 1, 2017, to September 30, 2022. Patients who underwent both an US and NCCT within 15 days of each other were included. Each stone was matched between modalities. Descriptive statistics, sensitivity, and specificity of US stone detection were calculated. A qualitative review of missed and overcalled stones was also performed.

Results: A total of 206 patients with a total of 368 stones were identified on NCCT, with 121 patients having US first. Overall, sensitivity and specificity of US were 64.4% and 40.3%, respectively. When US was performed first, sensitivity was 66.7% and specificity dropped to 18.0%. In contrast, when NCCT was performed first, sensitivity was 58.7% and specificity increased to 76.4%.

Conclusions: In our cohort, US sensitivity and specificity in detecting renal stones were consistent with prior reports. We demonstrate that the specificity of US can be improved if a NCCT is done first. Stone size tends to be overestimated on US, especially for smaller stones.