A new technique to prevent curling of guide wire in urinary bladder during J stent insertion with flexible cystoscope

Authors

  • Nasir Mahmood Western Memorial Regional Hospital, Corner Brook NL, Canada
  • Tahir Pasha

DOI:

https://doi.org/10.5489/cuaj.3079

Abstract

Insertion of J stent is a very common procedure performed by urologists. This procedure is often performed to relieve ureteral obstruction due to stones, tumours, ureteral kink, or stricture on urgent basis. An increasing number of urologists are using a flexible cystoscope and local anaesthetic for J stent insertion. Occasionally, the guide wire curls in the bladder, making it impossible to insert the J stent. Here, we describe a simple method to overcome this problem using modified ureteral dilator, which is usually available in the cystoscopy suite.

Downloads

Download data is not yet available.

Author Biography

Nasir Mahmood, Western Memorial Regional Hospital, Corner Brook NL, Canada

Consultant Urologist

Downloads

Published

2016-01-14

How to Cite

Mahmood, N., & Pasha, T. (2016). A new technique to prevent curling of guide wire in urinary bladder during J stent insertion with flexible cystoscope. Canadian Urological Association Journal, 10(1-2), E34–5. https://doi.org/10.5489/cuaj.3079

Issue

Section

Case Report